BJFDV - CRC WASP AND HORNET SPRAY #14001
- MSDS: BJFDV
- Manufacturer: C R C CHEMICALS U S A
- Product Name: CRC WASP AND HORNET SPRAY #14001
- National Stock Number: 6840-00-459-2443
Product Identification
Product ID:CRC WASP AND HORNET SPRAY #14001
MSDS Date:03/01/1990
FSC:6840
NIIN:00-459-2443
MSDS Number: BJFDV
Responsible Party
WARMINSTER, PA 18974-2820
US
Emergency Phone: 215-674-4300
Info Phone: 215-674-4300
Preparer: ALLEN B. REED
Cage: IO004
Contractor
Telephone: 215-674-4300/800-424-9300
Cage: 10136
Ingredients
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 84.75%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
STODDARD SOLVENT
CAS: 8052-41-3
RTECS: WJ8925000
Fraction By Weight: 11.0%
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM; 9293
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 4.0%
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM/30000STEL;93
RESMETHRIN
CAS: 10453-86-8
RTECS: GZ1310000
Fraction By Weight: 0.25%
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE, SKIN & RESPIRATORY TRACT
IRRITATION. CHRONIC: MAY CAUSE DERMITITIS UPON PROLONGED EXPOSURE.
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:EYES:BURNING AND IRRITATION. SKIN:DRYING AND
DEFATTING. INHALATION:HEADACHE, DIZZINESS, ANESTHESIA, AND
ASPHYXIA. INGESTION:NOT LIKELY TO OCCUR.
Medical Cond Aggravated by Exposure:PERSONS WITH EYE, SKIN, AND
RESPIRATORY DISORDERS MAY BE AT INCREASED RISK.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING GIVE CPR.
CALL A PHYSICIAN. EYE: IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER
FOR 15 MINUTES. CALL A PHYSICIAN. SKIN: WASH WITH PLENTY OF SOAP &
WATER. REMOVE CONTAMINATED CLOTHING/SHOES. INGESTION: DO NOT
INDUCE VOMITING. GIVE NOTHING BY MOUTH IF UNCONSCIOUS. GET
IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS(HYDROGEN CHLORIDE,
CHLORINE, AND SOME PHOSGENE).
Accidental Release
Spill Release Procedures:IF CONTAINER BEGINS TO LEAK (THROUGH PUNCTURE,
ETC.) ALLOW IT TO DISCHARGE COMPLETELY IN WELL VENTILATED AREA,
THEN DISPOSE IN SAFE PLACE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA. PROTECT CONTAINERS FROM PHYSICAL DAMAGE. DO NOT EXPOSE TO
TEMPERATURES ABOVE 130 DEG. F.
Other Precautions:SINCE VAPORS ARE HEAVIER THAN AIR, AEROSOLS SHOULD
NOT BE USED IN CONFINED AREAS OR LOW SPOTS WITHOUT ADEQUATE
VENTILATION. IF VAPORS ARE SUSPECTED IN A LOW PRESSURE AREA, DO NOT
ENTER UNLESS SPECIAL BREATHING APPARATUS IS USED.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:NOT APPLICABLE. FOR OUTDOOR USE ONLY.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:SAFETY GLASSES RECOMMENDED.
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER
RECOMMENDED. INDUSTRIAL-TYPE WORK CLOTHING.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
FOOTWEAR.
Supplemental Safety and Health
DO NOT GET ON SKIN, IN EYES OR ON CLOTHING. DO NOT BREATHE VAPORS OR
MISTS.
Chemical Properties
HCC:V2
Boiling Pt:B.P. Text:165F,74C
Vapor Density:>AIR
Spec Gravity:1.190
Solubility in Water:INSOLUBLE
Appearance and Odor:A YELLOWISH LIQUID WITH A CHLORINATED SOLVENT ODOR.
Percent Volatiles by Volume:>99.0
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS AND REACTIVE METALS.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN OPEN FLAME
MAY RESULT IN HALOGEN ACIDS AND CARBON DIXOIDE.
Disposal
Waste Disposal Methods:AEROSOL CONTAINER IS NOT REFILLABLE. DO NOT
ATTEMPT TO RECHARGE. WHEN CONTAINER IS EMPTY, DISCARD IN SAFE
PLACE. DO NOT PUNCTURE OR THROW IN FIRE. DISPOSAL SHOULD BE MADE IN
ACCORDANCE WITH ALL APPLI CABLE FEDERAL, STATE AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.